4. Specifications
VE.Bus Smart Dongle | Specifications |
|---|---|
Operating Input voltage range (Vbat) | 8 – 70Vdc |
Current draw (@12V) - BLE not connected to VictronConnect, VE.Bus connected | Not joining a VE.Smart network <6mA Joining a VE.Smart network <9mA |
Current draw (@12V) BLE connected to VictronConnect, VE.Bus connected | Not joining a VE.Smart network <7mA Joining a VE.Smart network <9mA |
Operating temperature | -20 to +50°C / 0 to 120°F |
Humidity | Max. 95% (non-condensing) |
Protection grade | IP20 |
Material and colour | ABS, matt black |
4.1. Compliance
SIMPLIFIED EU DECLARATION OF CONFORMITY: Hereby, Victron Energy B.V. declares that the VE.Bus Smart dongle is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://ve3.nl/6E.
UK PSTI STATEMENT OF COMPLIANCE: We, Victron Energy B.V., confirm that our product VE.Bus Smart dongle complies with the security requirements outlined in Schedule 1 of The Product Security and Telecommunications Infrastructure (Security Requirements for Relevant Connectable Products) Regulations 2023. The official Statement of Compliance can be downloaded from https://ve3.nl/6E.